Name battery-state-notif
Description The battery state has changed
Includes Message
Battery State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState N/A
1 error The battery has failed a periodic battery test and
may need to be serviced, or one or more of the
batteries have voltages that threaten the system’s
ability to backup data in the event of a power loss.
2 warn The batteries may be charging after being used,
this is expected after power loss. Alternatively,
the battery voltages may be below specification
but not dangerously low.
3 good The batteries are all operating properly.
4 warnHigh Battery voltages or currents are above
specification, but not dangerously high.
5 errorHigh Battery voltages or currents are dangerously high;
the system should be serviced.
6 noDevice N/A
7 notMonitored Monitoring has been turned off to suppress
warnings. Normal in systems without batteries.
RamSan-300/320/325 User’s Manual - 116 -