RamSan-325/325c User’s Manual - 84 -
Via Text Management
From the Telnet Main Menu, select “Controller setup
Select “Select controller
Choose a controller from the sub-menu and press [ENTER]
Figure 7-2: Controller Setup via Text Management Interface
The top of this menu indicates the controller’s current settings.
To change the topology:
Select “Change topology
Choose the controller’s topology from the sub-menu and press
[ENTER]
To change the link speed:
Select “Change link speed
Choose the controller’s link speed from the sub-menu and press
[ENTER]
All modifications are visible at the top of the menu.
To save any changes:
Select “Save changes and exit
Generally, selecting auto-detect for topology and link speed provides you
with the proper settings for your system. If the Controller Setup screen
displays these settings as “Unkn” (See Figure 7-3: Auto-Detect Error)
once you have saved the changes, you must configure the link speed and
topology manually.